Research Article
Fabrication of Cement, Polymer, and Metal-Matrix Fibre Composites by Gravity-Assisted Liquid-Binder Infiltration: A Practical Approach
Table 2
Flow test results for magnesium phosphate/steel fibre arrays.
| Volume fractionโโ (%) | Fibre spacing (horizontal) โโ (mm) | Fibre spacing (vertical) โโ (mm) | Fibre diameterโโ (mm) | Infiltration distanceโโ (mm) | () |
| 5 | 0.40 | 0.22 | 0.12 | 3.04 | 0.70 | 3 | 0.55 | 0.26 | 0.12 | 10.1 | 2.62 | 2 | 0.59 | 0.27 | 0.12 | 12.1 | 4.70 | 16 | 0.55 | 0.56 | 0.42 | 10.3 | 1.06 | 15 | 0.62 | 0.58 | 0.42 | 14.4 | 1.49 | 14 | 0.71 | 0.60 | 0.42 | 43.2 | 2.16 | 16 | 0.59 | 0.50 | 0.50 | 12.2 | 1.09 | 13 | 0.64 | 0.50 | 0.50 | 17.1 | 1.58 | 8 | 0.68 | 0.50 | 0.50 | 21.1 | 2.90 |
|
|