Research Article
Experimental Validation of Upward Electrospinning Process
Table 1
List of samples and different parameters used.
| Sample no. | Conc. % | Voltage (KV) | Distance (cm) | Flow rate (μL/min) | Needle gauge (G) | Fibre diameter (nm) |
| 1 | 10 | 15 | 7.5 | 25 | 22 | 100.62 | 2 | 10 | 15 | 15 | 50 | 27 | 77.27 | 3 | 10 | 15 | 7.5 | 25 | 27 | 80.45 | 4 | 10 | 15 | 7.5 | 50 | 27 | 43.23 | 5 | 10 | 15 | 15 | 25 | 22 | — | 6 | 10 | 15 | 7.5 | 50 | 22 | 82.27 | 7 | 10 | 15 | 15 | 50 | 22 | 55.43 | 8 | 10 | 30 | 7.5 | 50 | 27 | 75.33 | 9 | 10 | 30 | 7.5 | 50 | 22 | 58.50 | 10 | 10 | 30 | 15 | 25 | 22 | 72.77 | 11 | 10 | 30 | 15 | 50 | 22 | 76.22 | 12 | 10 | 30 | 7.5 | 25 | 22 | 78.50 | 13 | 10 | 30 | 15 | 50 | 27 | 55.10 | 14 | 10 | 30 | 15 | 25 | 27 | 53.47 | 15 | 10 | 30 | 7.5 | 25 | 27 | 75.40 | 16 | 20 | 15 | 7.5 | 25 | 27 | 234.78 | 17 | 20 | 15 | 7.5 | 50 | 22 | 288.92 | 18 | 20 | 15 | 7.5 | 25 | 22 | 289.05 | 19 | 20 | 15 | 7.5 | 50 | 27 | 606.80 | 20 | 20 | 30 | 15 | 50 | 22 | 196 | 21 | 20 | 30 | 7.5 | 50 | 22 | 353.4 | 22 | 20 | 30 | 15 | 25 | 22 | 156.25 | 23 | 20 | 30 | 7.5 | 25 | 22 | 268 | 24 | 20 | 30 | 15 | 25 | 27 | 171.83 | 25 | 20 | 30 | 7.5 | 50 | 27 | 294.94 |
|
|