Research Article
Relationship between Damping Factor and Compressive Residual Stress for Shot-Peened Austenitic Stainless Steel
Table 6
Damping factor and CRSF for Shot-peened sample.
| Almen Intensity | At 0.03 mm | At 0.06 mm depth | At 0.12 mm depth | Damping Factor | CRSF (MPa) | Damping Factor | CRSF (MPa) | Damping Factor | CRSF (MPa) |
| 1 A | 0.07829 | −300 | 0.07001 | −340 | 0.06273 | −420 | 3 A | 0.08094 | −340 | 0.07109 | −360 | 0.06472 | −500 | 4.5 A | 0.08297 | −360 | 0.07255 | −400 | 0.06735 | −540 | 6 A | 0.08307 | −360 | 0.07613 | −440 | 0.06829 | −560 |
|
|