Research Article
Optimum Design of TMD System for Tall Buildings
Table 3
Properties of TMDs used in testing models in both
,
directions as Zahrai and Ghannadi-Asl [
14].
| No. TMDs | (ton) | μ% | | | | |
| 1 | 216 | 0.050 | 0.940 | 0.051 | 152.789 | 83.029 | 2 | 108 | 0.025 | 0.970 | 0.026 | 40.597 | 21.797 | 4 | 54 | 0.013 | 0.985 | 0.013 | 10.467 | 5.586 | 5 | 43.2 | 0.010 | 0.988 | 0.011 | 6.744 | 3.594 | 8 | 27 | 0.006 | 0.992 | 0.007 | 2.658 | 1.414 | 10 | 21.6 | 0.005 | 0.994 | 0.005 | 1.706 | 0.907 | 16 | 13.5 | 0.003 | 0.996 | 0.003 | 0.670 | 0.356 | 20 | 10.8 | 0.002 | 0.997 | 0.003 | 0.429 | 0.228 | 32 | 6.75 | 0.002 | 0.998 | 0.002 | 0.168 | 0.089 | 40 | 5.4 | 0.001 | 0.998 | 0.001 | 0.108 | 0.057 | 80 | 2.7 | 0.001 | 0.999 | 0.001 | 0.027 | 0.014 | 160 | 1.35 | 0.000 | 1.000 | 0.000 | 0.007 | 0.004 | 164 | 1.32 | 0.000 | 1.000 | 0.000 | 0.006 | 0.003 | 320 | 0.68 | 0.000 | 1.000 | 0.000 | 0.002 | 0.001 |
|
|