Research Article

Teager Energy Based Filter-Bank Cepstra in EEG Classification for Seizure Detection Using Radial Basis Function Neural Network

Table 2

Percentage average accuracy of RBFNN analysis using linear, logarithmic, and Mel scale TE-FB-CEP methods ( , , and ) for composite vector-1 in discriminating eight classification problems (CPs).

CPLinear scale TE-FB-CEPLogarithmic scale TE-FB-CEPMel scale TE-FB-CEP

197.4097.9398.09
296.3797.0596.13
395.3196.9295.29
498.5798.8998.55
596.5098.1196.27
697.1898.0196.88
797.0898.0997.63
898.7398.9498.65