Real power distribution pertaining to the winter demand of the system |
Generators and their bus locations | Common | Contribution of the generator to the real power load of the common in kW | Contribution of the generator to the real power losses of the common in kW | Link | Contribution of the generator to the real power losses on the links in kW | Contribution of the generator to the total real power load of the system in kW | Contribution of the generator to the total real power losses of the system in kW | Participation factor of the generator to the total real power load in the system | Participation factor of the generator to the total real power losses in the system |
|
G1 at 3rd bus | C1 | 1776 | 15.21 | L1 | 0.2 |
1854 |
15.41 |
0.4159 |
0.30 |
C2 | — | — | L2 | — |
C3 | — | — | L3 | — |
C4 | — | — | L4 | — |
C5 | 77.97 | — | — | — |
|
G2 at 9th bus | C1 | — | — | L1 | — |
938 |
12.16 |
0.2104 |
0.2355 |
C2 | 810 | 11.77 | L2 | 0.39 |
C3 | — | — | L3 | — |
C4 | 128 | — | L4 | — |
C5 | — | — | — | — |
|
G3 at 31st bus | C1 | — | — | L1 | — |
1666 |
24.05 |
0.3737 |
0.46 |
C2 | — | — | L2 | — |
C3 | 1488 | 23.83 | L3 | 0.09 |
C4 | 112.0 | — | L4 | 0.13 |
C5 | 66.02 | — | — | — |
|
Real power generation of G1 is 1870 kW, G2 is 950 kW, and G3 is 1690 kW, respectively |
|
Reactive power distribution pertaining to the winter demand of the system |
Generators and their bus locations | Common | Contribution of the generator to the reactive power load of the common in kVAR | Contribution of the generator to the reactive power losses of the common in kVAR | Link | Contribution of the generator to the reactive power losses on the links in kVAR | Contribution of the generator to the total reactive power load of the system in kVAR | Contribution of the generator to the total reactive power losses of the system in kVAR | Participation factor of the generator to the total reactive power load in the system | Participation factor of the generator to the total reactive power losses in the system |
|
G1 at 3rd bus | C1 | 1092 | 15.66 | L1 | 0.51 |
1160 |
18.97 |
0.4203 |
0.452 |
C2 | — | — | L2 | — |
C3 | — | — | L3 | — |
C4 | 38.2 | — | L4 | 2.8 |
C5 | 30.0 | — | — | — |
|
G2 at 9th bus | C1 | — | — | L1 | — |
574 |
9 |
0.2079 |
0.2144 |
C2 | 492 | 8.97 | L2 | 0.03 |
C3 | — | — | L3 | — |
C4 | 81.8 | — | L4 | — |
C5 | — | — | — | — |
|
G3 at 31st bus | C1 | — | — | L1 | — |
1026 |
14 |
0.3718 |
0.3336 |
C2 | — | — | L2 | — |
C3 | 972 | 12.6 | L3 | 1.4 |
C4 | — | — | L4 | — |
C5 | 54.0 | — | — | — |
|
Reactive power generation of G1 is 1179 kVAR, G2 is 583 kVAR, and G3 is 11040 kVAR, respectively |
|