Research Article

Study and Application of Polymer Film-Forming Shielding Plugging Drilling Fluid System

Table 1

Sand bed leakage experiment.

Formula
(g/cm3)
FL 
(mL)
Experiment condition
(0.7 MPa, 30 min, 20~40 mesh quartz sand, room temperature)

Emulsion slurry system1.494Instantaneous loss
Slurry + 1% MFDJ1.493.6Instantaneously soak to 6 cm and 10 minutes later soak to 8.5 cm. There is no increase. Forcing to 1.2 MPa, there are also no changes.
Slurry + 2% MFDJ1.493Instantaneously soak to 2.8 cm and 10 minutes later soak to 3.5 cm. There is no increase. Forcing to 1.2 MPa, there are also no changes.
Slurry + 3% MFDJ1.502.8Instantaneously soak to 2 cm and 10 minutes later soak to 2.5 cm. There is no increase. Forcing to 1.2 MPa, there are also no changes.
Slurry + 4% MFDJ1.502.4Instantaneously soak to 1.7 cm and 10 minutes later soak to 2 cm. There is no increase. Forcing to 1.2 MPa, there are also no changes.

MFDJ is a kind of polymer film-forming shielding plugging addictive.