Performance analysis of all features.

FEATURETraining (%)Testing (%)
AccuracyTPRTNRFNRAccuracyTPRTNRFNR

Intensity histogram8073.386.726.777.5758025
GLCM86.78093.320908010020
GLRLM9086.79313.39595955
Invariant moments6586.743.313.372.5905510
Mixed feature91.793.3906.792.595905