Research Article

In Vitro Corrosion Studies of Surface Modified NiTi Alloy for Biomedical Applications

Table 2

Composition of simulated body fluids used in the present study.

ChemicalsPBS (g/L)Hanks’ (g/L)

NaCl88
CaCl20.14
KCl0.20.4
MgCl2·6H2O0.1
MgSO4·7H2O0.1
NaHCO30.35
Na2HPO41.15
Na2HPO4·2H2O0.12
KH2PO40.20.06
Glucose1