Conversion results of IEEE 30 bus systems for the load of 283.4 MW without line loss.
| Unit power output | PSO | CPSO | WIPSO | MRPSO |
| 1 (MW) | 81.047 | 78.043 | 83.0324 | 73.0231 | P2 (MW) | 63.1092 | 63.0197 | 60.0947 | 62.1528 | 5 (MW) | 45.6863 | 48.632 | 44.023 | 46.8732 | 8 (MW) | 32.6824 | 34.0721 | 33.7961 | 34.0872 | 11 (MW) | 32.1054 | 27.0921 | 32.0823 | 28.4035 | 13 (MW) | 28.731 | 32.5401 | 30.432 | 38.8732 | Total power output | 283.361 | 283.399 | 283.460 | 283.413 | Fuel cost ($/h) | 1434747 |