Research Article

Multiobjective Economic Load Dispatch Problem Solved by New PSO

Table 5

Conversion results of IEEE 30 bus systems for the load of 283.4 MW with line loss.

Unit power outputPSOCPSOWIPSOMRPSO

1 (MW)147.03146.034147.581145.7801
2 (MW)43.11446.073246.88943.0912
5 (MW)36.66134.074247.070543.07654
8 (MW)23.01926.019816.786324.0763
11 (MW)25.37724.10824.721923.1732
13 (MW)27.63226.091119.892523.0453
Loss (MW)19.43519.000319.540718.8468
Total power output302.835302.400302.9407302.2468
Fuel cost ($/h)2617397.12607622.22661326.72575426.4
Environmental emission (Ton/h)163675.87162228.52167729.08162153.591
Total cost ($/h)
Time (sec)0.51650.50320.495410.48203