Research Article
Congenital Hypothyroidism: An Audit and Study of Different Cord Blood Screening TSH Values in a Tertiary Medical Centre in Malaysia
Table 4
Comparison of different screening cut-off values.
| Cord blood TSH cut-off (mIU/L) | Positive screened (recall rates) () | True positives (confirmed CH by repeated TFT at days 3–5) | False positives | Positive predictive value | Incidence | False positive rate |
| >30 | 84 (0.32%) | 11 | 73 | 13% | 1:2341 | 0.28% | >25 | 163 (0.63%) | 17 | 146 | 10.6% | 1:1515 | 0.56% | >20 | 340 (1.3%) | 17 | 323 | 5% | 1:1515 | 1.2% |
|
|