Research Article
Identification of Induction Motor Parameters in Industrial Drives with Artificial Neural Networks
Table 1
Induction motor parameters.
| 1.1 kW, 1415 RPM, 415 V,
2.77 A, 3 phases, 4 pole, 50 Hz |
| Stator resistance : 6.03 Ω | Rotor leakage inductance : 29.9 mH | Stator leakage inductance : 29.9 mH | Magnetizing inductance : 489.3 mH | Rotor resistance : 6.085 Ωat 50 Hz | Moment of inertia : 0.011787 kgm2 |
|
|