Research Article

Identification of Induction Motor Parameters in Industrial Drives with Artificial Neural Networks

Table 1

Induction motor parameters.

1.1 kW, 1415 RPM, 415 V, 2.77 A, 3 phases, 4 pole, 50 Hz

Stator resistance : 6.03 Ω
Rotor leakage inductance : 29.9 mH
Stator leakage inductance : 29.9 mH
Magnetizing inductance : 489.3 mH
Rotor resistance : 6.085 Ωat 50 Hz
Moment of inertia : 0.011787 kgm2