Research Article

Application of a Data-Driven Fuzzy Control Design to a Wind Turbine Benchmark Model

Table 4

Monte-Carlo analysis for the fuzzy controller: NSSE% values.

Test case Partial load Full load

Best case 19.37% 9.57%
Average case 21.19% 11.94%
Worst case 23.19% 13.94%