Review Article

Hybrid Processing Combining Electrostatic Levitation and Laser Heating: Application to Terrestrial Analogues of Asteroid Materials

Table 1

Comparison of density data measured in this study and that reported in the literature. Note that the data were compared for identical temperatures.

  Fe75Ni25 (kg/m3)Difference (%)Fe50Ni50 (kg/m3)Difference (%)Fe25Ni75 (kg/m3)Difference (%)Technique

This study (1550°C)717073007540Levitation
This study (1540°C)718073107550Levitation
Benedicks et al. (1550°C) [25]7220−0.607360−0.8975000.51Manometer
Dzhemilev et al. (1550°C) [26]7270−1.347430−1.737560−0.33Sessile drop
El-Chansan et al. (1540°C) [27]7200−0.337360−0.8175200.36Expansion
Popel et al. (1550°C) [28]7190−0.217360−0.7975100.34Sessile drop
Sharan et al. (1550°C) [29]7240−0.967410−1.557570−0.39Sessile drop
Watanabe et al. (1550°C) [30]7210−0.467400−1.387580−0.53Maximum bubble pressure