Research Article

Optical Biosensor Based on Microbendings Technique: An Optimized Mean to Measure the Bone Strength

Table 2

Performance analysis of neural network based biosensor with varying layers.

Serial numberNumber of layersMean square error (mse)Percentage accuracyNumber of epochs

110.04323193.859649%27
220.04562392.543860%19
340.04995994.298246%6
450.02560396.929825%31
560.03549995.175439%28
680.03407693.421053%10
7100.02933896.929825%10
8120.03202795.614035%21