Comparison of CMV control techniques.

Without filterWith filter ( = 1.2 mH, = 100 uF)
SPWM technique Line voltage
(kV)
Line current
(amps)
Line voltage
(kV)
Line current
(amps)
Average NPP (Vnp) voltsAverage CMV (Vcm) volts
% THD % THD % THD % THD

PD8.120.5125428.3915.63.132560.868.359.2
POD8.125.9725032.5715.62.922540.7816.169.1
PD + off-set voltage8.07.8125418.1615.63.242580.851.425.3
POD + off-set voltage8.135.6325743.4315.63.392590.778.359.6