Research Article

Development and Validation of RP-HPLC Method for Quantitative Estimation of Vinpocetine in Pure and Pharmaceutical Dosage Forms

Table 4

Intraday and interday precision of HPLC method.

Sr. no.Concentration (μgmL−1)Standard solutionSample solution
Intra-day precisionInter-day precisionIntra-day precisionInter-day precision

12003479501348456634813323489214
22003479005348411234819873489741
32003478987348399134822443490301
42003479227348497734815103489748
52003479808348500434819933489849
62003479777348466934822143490488
Mean3479384348455334818803489890
SD367.100425.941375.626453.331
%RSD0.0110.0120.0110.013