Chromatography Research International / 2016 / Article / Tab 2 / Research Article
Validated Stability Indicating Chromatographic Method for the Simultaneous Estimation of Camylofin with NSAID Drugs and a New Approach of Method Transfer from Classical HPLC to a Modern UPLC Instrument Table 2 Accuracy levels (%) study results.
Drugs Level % Set no. Drug amount added (µ g/mL) Drug amount found (µ g/mL) % recovery % mean Recovery % RSD Mean of absolute % bias CMF 50 1 25.18 25.23 98.84 99.49 0.57 0.200 2 24.78 24.86 99.70 3 25.62 25.64 99.92 100 1 49.39 49.53 99.72 99.91 0.16 0.088 2 49.61 49.60 100.01 3 49.57 49.57 99.99 150 1 79.98 79.94 100.05 100.01 0.04 0.004 2 80.49 80.52 99.97 3 81.02 81.02 100.01 DCF 50 1 25.43 25.42 100.02 99.96 0.17 0.027 2 25.47 25.44 100.10 3 25.18 25.24 99.77 100 1 49.57 49.58 99.99 99.99 0.06 0.007 2 49.54 49.57 99.94 3 49.61 49.58 100.05 150 1 74.88 74.86 100.01 100.05 0.09 0.053 2 75.10 74.99 100.15 3 74.94 74.95 99.99