Clinical Study

Multicenter Randomized Trial of 10-French versus 11.5-French Plastic Stents for Malignant Biliary Obstruction

Table 3

Total complications by stent size.

Complication10 Fr ( )11.5 Fr ( )
Number (%) of patientsMedian time to complication (Days)Number (%) of patientsMedian time to complication (Days)

Death95 (83%)12095 (80%)170
Death before occlusion66 (57%)82.566 (55%)114.5
Stent obstruction (all causes)39 (34%)10738 (32%)147
Stent occlusion35 (30%)11036 (30%)147
Stent migration5 (4%)615 (4%)56
Tumor overgrowth1 (1%)143 (3%)74