Research Article

Small Sample Fiber Full State Diagnosis Based on Fuzzy Clustering and Improved ResNet Network

Table 1

Classification and analysis of OTDR curves for different status of fibers.

CodeRunning stateCurve typesCurve characteristic

f0HealthyNormal OTDR curveThe curve has a sharp peak at the beginning and end, and becomes flat in the middle of it

f1SubhealthyThe cable is overbentThere are “small steps” in the middle
f2The bending radius of the cable is rather smallThe curve fluctuates in the intermediate stage
f3The breakpoint is too close to the test point or in a blind spotThe curve has no middle flat stage and no end peak

f4FaultFiber breakA large peak appeared in the middle flat stage of the curve
f5Dirty on the end of the cable or poor quality on the end of the surfaceThere is no reflection spike at the end of the curve