Research Article

Analysis of Confined Jet Impingement in Converging Annular Microchannel Heat Sinks

Table 3

A comparison between the experimental and numerical Nu number of Tang et al. [45] and numerically calculated Nu number of present study.

Cone angleExperimental Nu
[45]
Numerical Nu
[45]
Numerical Nu
(present study)
Deviation from experimental resultsDeviation from numerical results

1,2381,254.61,2201.45%2.7%
45°1,3471,3801,3033.24%5%