Review Article

A Review of Membrane Electrode Assemblies for the Anion Exchange Membrane Water Electrolyser: Perspective on Activity and Stability

Table 1

Comparison of the three main low-temperature electrolyser technologies.

Electrolyser →AEMWEPEMWEAWE

Circulating electrolyte0.1-1.0 M KOH [18, 19]Deionised water [7]4.5-8.0 M KOH [18, 19]
Current density (A cm–2)1-2 [18, 19]1-3 [7, 19]0.2-0.8 [19]
Cell voltage (V)1.4-2.0 [18, 19, 20]1.4-2.3 [7, 21]1.4-3.0 [19]
Temperature (°C)60-80 [18, 19]50-90 [7]80-120 [22]
Anode (OER)NiFeOx [22]IrO2 [7, 22]Ni, Ni-Co [22]
Cathode (HER)NiCo [22]Pt/C [7, 22]Ni, Ni-Mo [22]
Efficiency (LHV%)52-75 [19, 23]50-68 [19]50-68 [19]
MaturitykW—small commercial unitsMW—large commercial unitsMW—mature
Stack life (yr)>5000 [19]20 000-90 000>90 000
Cost (stack) ( kW–1)320-1000 (1-10 MW) [24, 25]360-900 (1-10 MW) [19, 25]240-600 (1-10 MW) [19, 25]
Degradation rate (μV h–1)5-1000 [18]5-200 [26, 27]5-20 [28, 29]

Some of these values have been calculated to euros based of 1 USD ≈0.91 EUR.