Research Article

Characterization and Beneficiation of an Egyptian Nepheline Syenite Ore

Table 3

Effect of the field intensity on the performance of the Carpco induced roll magnetic separator for cleaning the nepheline syenite ore.

Current intensity,
Ampere
Field intensity,
Gauss
ProductProduct weight,
%
Assay,
Fe2O3 %
Distribution,
Fe2O3 %

3,500Magnetic18.427.885.8
0.5Nonmagnetic81.61.614.2
Total1006.42100

7,100Magnetic21.125.291.1
1.0Nonmagnetic78.91.48.9
Total1006.43100

14,500Magnetic25.421.893.0
2.0Nonmagnetic74.61.27.0
Total1006.43100

18,000Magnetic27.220.594.9
3.0Nonmagnetic73.21.15.1
Total1006.35100

Feed size fraction: −0.25 mm; Feed rate, kg/h: 24.