Research Article
60Co-Gamma Ray Induced Total Dose Effects on P-Channel MOSFETs
Table 1
Experimental results of virgin and gamma (γ) irradiated P-channel MOSFETs.
| -Dose | (V) | (10−4 mho) | (mV/decade) | (mA) |
| Virgin | −0.69 | 30.90 | 9.0 | 19.06 | 1 Krad | −0.72 | 30.60 | 9.62 | 18.81 | 10 Krad | −0.84 | 29.30 | 10.12 | 18.17 | 100 Krad | −1.39 | 21.32 | 10.58 | 14.63 | 500 Krad | −1.95 | 11.07 | 13.34 | 11.12 | 1 Mrad | −2.41 | 4.04 | 16.10 | 8.13 |
|
|