Research Article
High Power Combline Filter for Deep Space Applications
Table 3
Estimation of multipaction margin for filters F2 and F3.
| Res. Number | Gap (mm) | |
Multipactor margin (dB) | F2 | F3 | F2 | F3 | F2 | F3 |
| 1 | 7.26 | 7.91 | 1017.7 | 1110.7 | 0.39 | 1.72 | 2 | 6.93 | 7.72 | 971.4 | 1083.9 | −1.61 | −1.69 | 3 | 7.12 | 7.91 | 998.0 | 1110.6 | −3.42 | −1.57 | 4 | 7.13 | 7.94 | 999.4 | 1115.2 | −2.11 | −2.05 | 5 | 7.13 | 7.94 | 999.4 | 1115.2 | −3.58 | −1.50 | 6 | 7.13 | 7.94 | 999.4 | 1115.2 | −2.19 | −2.10 | 7 | 7.13 | 7.94 | 999.4 | 1115.2 | −3.40 | −1.29 | 8 | 7.13 | 7.91 | 999.4 | 1110.6 | −2.05 | −2.00 | 9 | 7.12 | 7.72 | 998.0 | 1083.9 | −3.04 | −0.77 | 10 | 6.93 | 7.91 | 971.4 | 1110.7 | −1.47 | 1.46 | 11 | 7.26 | — | 1017.7 | — | 0.94 | — |
|
|