Research Article

Analysis of Loss of Flow Events on Brazilian Multipurpose Reactor Using the Relap5 Code

Table 4

Reference and calculated results for 30 MW power condition.

ParametersReferenceRELAP5Error (%)*Acceptable error (%)

Inlet and outlet core coolant temperatures (K)311.0/320.0 311.0/320.0 0.0/0.00.5
Inlet and outlet pool coolant temperatures (K)306.0/—307.0/312.30.40.5
Mass flow rate from pool to core by chimney (kg/s)83.383.1 0.22.0
Inlet and outlet core mass flow rate (kg/s)750.0/833.0748.0/831.00.2/0.22.0

Error = 100 × (calculation − reference)/reference.