Research Article

Probabilistic Structural Integrity Analysis of Boiling Water Reactor Pressure Vessel under Low Temperature Overpressure Event

Table 7

Fractions of CPI and CPF by flaw categories.

Flaw category32 EFPY64 EFPY
Total CPITotal CPFTotal CPITotal CPF
1.38 × 10−71.30 × 10−74.13 × 10−73.85 × 10−6
% of CPICPI% of CPFCPF% of CPICPI% of CPFCPF

Flaw Category 1Inner0.081.10 × 10−100.033.90 × 10−110.208.26 × 10−100.083.08 × 10−10
Outer00000000

Flaw Category 2Inner94.671.31 × 10−799.971.30 × 10−793.523.86 × 10−799.923.85 × 10−6
Outer00000000

Flaw Category 3Inner00000000
Outer5.257.25 × 10−9006.282.59 × 10−800

The conditional probabilities should be multiplied by 10−3/year (the occurrence frequency of LTOP transient) to determine the fracture and failure frequencies per year.