Research Article

A Comparative Study of the Stress Distribution in Different Endodontic Post-Retained Teeth with and without Ferrule Design—A Finite Element Analysis

Table 1

Dimensions of structures in FE model [6, 1417].

No.Different parts in FE modelDimensions (mm)

(1)Tooth [14]
  (a) Root length13.0 mm
  (b) Root diameter6.0 mm (cervical)
(2)Periodontal ligament [15]0.2 mm (width)
(3)Cortical bone [16]1.2 mm (thickness)
(4)Gutta Percha [17]4.5 mm (length)
(5)Endodontic post [17]
 Length10.5 mm
 Diameter1.5 mm (parallel post)
0.6–1.5 mm (tapered post)
10.5 mm (height)
(6)Crown [17]1.2 mm (thickness at cervical margin)
2.0 mm (thickness at incisal edge)
(7)Core [17]6.5 mm (height) + 2 mm residual dentin
(8)Ferrule design [6]1.5 mm (length)