Clinical Study

Simultaneous Use of Cannulated Reamer and Schanz Screw for Closed Intramedullary Femoral Nailing

Table 1

Comparison of the two groups.

Group IGroup II 𝑃 value
MeanStandard deviationMeanStandard deviation

The guide wire insertion time (min) (range)26.57 (17–33)4.5530.87 (23–44)5.55Very significant (.002)
Time for nail insertion and its distal locking (min) (range)27.93 (20–40)4.6827.83 (21–45)6.34NS (.94)
Total operative time (min) (range)68.03 (55–81)7.1369.93 (51–82)8.68NS (.35)
The radiation exposure during guide wire insertion (range)12.33 (7–25)4.2522.1 (9–31)5.24Extremely significant ( 𝑃 < . 0 0 0 1 )
The radiation exposure during nail insertion and its distal locking (range)25.27 (16–37)4.5226.17 (19–37)5.04NS (.47)
Total exposures in procedure (range)37.6 (27–51)6.6248.27 (29–60)7.59Extremely significant ( 𝑃 < . 0 0 0 1 )
Total fluoroscopic time (minutes) (range)0.19 (0.13–0.25)0.0320.24 (0.14–0.3)0.039Extremely significant ( 𝑃 < . 0 0 0 1 )

NS: Not significant.