Grid independence study for the value of the Reynolds number of 100 and Prandtl number of 0.71.

ReTotal number of cells in the domainSpacing of the first grid point from the cylinderTime-averaged Nusselt number

1001165000.004  𝑑 5.5961
1165000.0015  𝑑 5.5843
1165000.001  𝑑 5.5741