Research Article
Continuous Positive Airway Pressure Adherence for Obstructive Sleep Apnea
Table 3
Results of backwards logistic regression predicting 1-year compliance. Eighty-three observations with 41 compliers used in this analysis.
| Variable | OR (95% CI) | Coefficient | -value |
| ln percentage of the population without a high school degree | 3.05 (1.03, 9.03) | 1.115 | .044 | ln time from initial sleep appointment to initial polysomnogram | 2.82 (1.14, 6.93) | 1.035 | .024 | ln total time from initial sleep appointment to receiving CPAP machine | 0.11 (0.03, 0.44) | −2.247 | .002 | Median household income | 1.04 (1.01, 1.08) | 0.043 | .010 |
|
|