Research Article

Continuous Positive Airway Pressure Adherence for Obstructive Sleep Apnea

Table 3

Results of backwards logistic regression predicting 1-year compliance. Eighty-three observations with 41 compliers used in this analysis.

VariableOR (95% CI)Coefficient 𝑃 -value

ln percentage of the population without a high school degree3.05 (1.03, 9.03)1.115.044
ln time from initial sleep appointment to initial polysomnogram2.82 (1.14, 6.93)1.035.024
ln total time from initial sleep appointment to receiving CPAP machine0.11 (0.03, 0.44)−2.247.002
Median household income1.04 (1.01, 1.08)0.043.010