Research Article

Optimum Alkaline Electrolyzer-Proton Exchange Membrane Fuel Cell Coupling in a Residential Solar Stand-Alone Power System

Table 3

Constants used to calculate potential losses for low-temperature PEMFC.

ConstantUnitsValue

in(mA·cm−2)3
r(kΩ·cm2)2.54 × 10−4
io(mA·cm−2)0.1
m(volts)2.11 × 10−5
n(cm2/mA)8 × 10−3