Simulation of Switched Reluctance Generator in Low and Medium Speed Operations for Wind Energy Application
Table 2
Optimal angles at different speed and voltage.
β
β
β
β
β
Volt
Turn on
Turn off
Dwell ()
Total instantane ous power
Instantan eous copper losses
50βV
16
34
18
51.7
15.3
100βV
18
34
16
196.6
56.2
150βV
22
34
12
339.3
72.5
325βV
29
37
8
933.8
111.7
19
41
22
1247.9
173.8
500βV
31
38
7
1662.7
140.7
21
41
20
2085.1
194.6
β
β
β
βrad/s
β
β
50βV
16
35
19
45.7
12.7
100βV
15
34
19
178
47.4
150βV
19
34
15
331.2
71.1
325βV
27
36
9
846.4
93.8
17
42
25
1171.5
159.3
500βV
29
37
8
1531.7
121.9
22
42
20
1951.5
177.8
β
β
β
βrad/s
β
β
50βV
15
35
20
39.7
9.7
100βV
13
34
21
160.9
39.6
150βV
16
34
18
320
69.2
325βV
24
36
12
849.5
96.1
16
43
27
1098.4
145.7
500βV
28
37
9
1460.2
112.7
19
42
23
1858.5
166.6
β
β
β
βrad/s
β
β
50βV
14
35
21
35.3
7.8
100βV
14
35
21
144.8
33.5
150βV
14
34
20
300
62.1
325βV
21
36
15
845.2
96.3
13
43
30
1052.7
136.2
500βV
26
37
11
1414.8
109.8
17
42
25
1794.4
158.8
We are committed to sharing findings related to COVID-19 as quickly as possible. We will be providing unlimited waivers of publication charges for accepted research articles as well as case reports and case series related to COVID-19. Review articles are excluded from this waiver policy. Sign up here as a reviewer to help fast-track new submissions.