Review Article

Advances in Asset Management Techniques: An Overview of Corrosion Mechanisms and Mitigation Strategies for Oil and Gas Pipelines

Table 4

Corrosion inhibitor risk categories.

Risk categoryMax inhibitor availabilityMax expected uninhibited corrosion rate (mm/yr)commentsProposed category name

10%0.4Benign Fluid, corrosion inhibitor use not anticipated. Predicted metal loss accommodated by corrosion allowanceBenign
250%0.7Corrosion inhibitor probably required but with expected corrosion rates there will time be time to review the need for inhibition based on inspection data.Low
390%3Corrosion inhibition required for majority of field life but inhibitor facilities need not be available from day one.Medium
495%6High reliance on inhibition for operational life time. Inhibitor facilities most be available from day one to ensure success High
5>95%>6Carbon steel and inhibition is unlikely to provide integrity for full field life. Select corrosion resistant material or plan for repair and replacementUnacceptable