Research Article

Comparative Study of Indentation Size Effects in As-Sintered Alumina and Alumina Shock Deformed at 6.5 and 12 GPa

Table 1

The relative percentages of changes in versus depth ( ) plots of Figure 4 along AB, BC and CD at a typical illustrative nanoindentation peak loads of 500 mN and 1000 mN for ARA, 6.5 GPa SA and 12 GPa SA samples.

Loads (mN)SampleAB (%)BC (%)CD (%)

ARA10.399.424.37
5006.5 GPa SA15.3413.066.80
12 GPa SA34.3830.5517.24

ARA4.322.582.32
10006.5 GPa SA14.3210.717.68
12 GPa SA39.8927.6220.44