Research Article

Joint Segmentation and Groupwise Registration of Cardiac Perfusion Images Using Temporal Information

Table 1

Summary of registration and segmentation performance on cardiac perfusion datasets. The values indicate average and standard deviations for all datasets.

Registration error (mm)Segmentation result
BeforeAfter registration 𝐷 𝑀 (%)
Registration 𝐽 𝑆 𝐺 𝑅 𝑀 𝑒 𝑡 1 𝑀 𝑒 𝑡 2 𝐽 𝑅 𝑆 𝐽 𝑆 𝐺 𝑅 𝑀 𝑒 𝑡 1 𝑀 𝑒 𝑡 2 𝐽 𝑅 𝑆

LV epicardium 2 . 2 ± 1 . 2 0 . 7 ± 0 . 1 1 . 0 ± 0 . 2 1 . 1 ± 0 . 1 0 . 8 ± 0 . 4 9 3 . 6 ± 0 . 7 9 0 . 1 ± 0 . 3 9 0 . 6 ± 0 . 6 9 2 . 1 ± 1 . 1
LV endocardium 2 . 8 ± 1 . 0 0 . 5 ± 0 . 2 0 . 9 ± 0 . 1 0 . 9 ± 0 . 2 0 . 7 ± 0 . 3 9 2 . 8 ± 0 . 6 8 8 . 9 ± 0 . 1 8 8 . 4 ± 0 . 3 9 2 . 1 ± 0 . 8
LV overall 2 . 6 ± 1 . 1 0 . 5 ± 0 . 2 0 . 9 ± 0 . 3 1 . 0 ± 0 . 1 0 . 7 ± 0 . 4 9 3 . 1 ± 0 . 5 8 9 . 4 ± 0 . 2 8 8 . 8 ± 0 . 8 9 2 . 1 ± 0 . 9