Research Article
Health Monitoring of Nuclear Structure Containment Using Strain Gauges to Assess the Integrity
Table 2
Strain Measurements from SMER’s—Pressure from 0 to 1.73 kg/cm2.
| SMER no. | Location | Legend | Microstrain at pressure up (kg/cm2) | 0 | 0.35 | 0.7 | 1.06 | 1.4 | 1.73 |
| On steel | | | | | | | SE-55 | Dome SG-1 opening, N-S | (S1) | 0 | 22.7 | 33.7 | 57.2 | 88.9 | 102.7 | SE-56 | Dome SG-1 opening, E-W | (S1) | 0 | 28.1 | 42.6 | 35.4 | 53.5 | 38.6 | SE-57 | Dome SG-1 opening, N-S | (S2) | 0 | 20.1 | 24.8 | −6.5 | 61.2 | 20.8 | SE-58 | Dome SG-1 opening, E-W | (S2) | 0 | 22.5 | 30.8 | 4.3 | 72.1 | 34.8 | SE-59 | Dome SG-1 opening, N-S | (S3) | 0 | 22.5 | 32.9 | 38.5 | 93.8 | 97.5 | SE-60 | Dome SG-1 opening, E-W | (S3) | 0 | 26.2 | 37.7 | 31.6 | 58.1 | 33.9 |
| On Concrete | | | | | | | SE-01 | Stressing gallery, 84.85M, outer side (N), V | A | 0 | 5.8 | 4.5 | 6.9 | 8.0 | 8.0 | SE-02 | Stressing gallery, 84.85M, inner side (N), V | B | 0 | 6.6 | 6.6 | 12.7 | 17.2 | 17.7 | SE-08 | ICW (O), 88.1M, (S), V | D | 0 | 0.8 | −4.9 | −8.6 | −7.0 | −13.0 | SE-25 | Ring beam, 133.5M, ICW (N), Cir | M | 0 | −9.1 | −14.4 | −16.6 | −34.7 | −28.1 |
|
|