Table of Contents
ISRN Orthopedics
Volume 2013, Article ID 173923, 5 pages
http://dx.doi.org/10.1155/2013/173923
Clinical Study

The Correlation of Serum Metal Ions with Functional Outcome Scores at Three-to-Six Years following Large Head Metal-on-Metal Hip Arthroplasty

Department of Orthopaedics, University Hospital of Wales, 84 Colchester Avenue Penylan, Cardiff, UK

Received 9 January 2013; Accepted 7 February 2013

Academic Editors: V. S. Nikolaou, C.-H. Tsai, and B. K. Weiner

Copyright © 2013 Sheethal Prasad Patange Subbarao et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Linked References

  1. D. E. Beverland and R. F. Spencer, “Hip resurfacing and metal-on-metal total hip arthroplasty,” HIP International, vol. 21, no. 3, pp. 277–278, 2011. View at Publisher · View at Google Scholar · View at Scopus
  2. J. M. Cuckler, K. D. Moore, A. V. Lombardi Jr., E. McPherson, and R. Emerson, “Large versus small femoral heads in metal-on-metal total hip arthroplasty,” Journal of Arthroplasty, vol. 19, no. 8, supplement 3, pp. 41–44, 2004. View at Publisher · View at Google Scholar · View at Scopus
  3. C. P. Delaunay, “Metal-on-metal bearings in cementless primary total hip arthroplasty,” Journal of Arthroplasty, vol. 19, no. 8, supplement 3, pp. 35–40, 2004. View at Publisher · View at Google Scholar · View at Scopus
  4. W. T. Long, L. D. Dorr, and V. Gendelman, “An American experience with metal-on-metal total hip arthroplasties: a 7-year follow-up study,” Journal of Arthroplasty, vol. 19, no. 8, pp. 29–34, 2004. View at Publisher · View at Google Scholar · View at Scopus
  5. H. Migaud, A. Jobin, C. Chantelot, F. Giraud, P. Laffargue, and A. Duquennoy, “Cementless metal-on-metal hip arthroplasty in patients less than 50 years of age: comparison with a matched control group using ceramic-on-polyethylene after a minimum 5-year follow-up,” Journal of Arthroplasty, vol. 19, no. 8, supplement 3, pp. 23–28, 2004. View at Publisher · View at Google Scholar · View at Scopus
  6. S. Giannini, M. Cadossi, E. Chiarello, C. Faldini, A. Moroni, and M. Romagnoli, “Hip resurfacing arthroplasty: a series of 140 consecutive hips with a minimum five year follow-up. A clinical, radiological and histological analysis,” HIP International, vol. 21, no. 1, pp. 52–58, 2011. View at Publisher · View at Google Scholar · View at Scopus
  7. D. W. Murray, G. Grammatopoulos, R. Gundle et al., “Hip resurfacing and pseudotumour,” HIP International, vol. 21, no. 3, pp. 279–283, 2011. View at Publisher · View at Google Scholar · View at Scopus
  8. “Medicines and Healthcare products Regulatory Agency (MHRA). Medical Device Alert: all metal-on-metal (MOM) hip replacements,” 2010, MDA/2010/033, http://www.mhra.gov.uk/Publications/Safetywarnings/MedicalDeviceAlerts/.
  9. K. De Smet, R. De Haan, A. Calistri et al., “Metal ion measurement as a diagnostic tool to identify problems with metal-on-metal hip resurfacing,” Journal of Bone and Joint Surgery A, vol. 90, supplement 4, pp. 202–208, 2008. View at Publisher · View at Google Scholar · View at Scopus
  10. F. S. Haddad, R. R. Thakrar, A. J. Hart et al., “Metal-on-metal bearings: the evidence so far,” Journal of Bone and Joint Surgery B, vol. 93, no. 5, pp. 572–579, 2011. View at Publisher · View at Google Scholar · View at Scopus
  11. J. Antoniou, D. J. Zukor, F. Mwale, W. Minarik, A. Petit, and O. L. Huk, “Metal ion levels in the blood of patients after hip resurfacing: a comparison between twenty-eight and thirty-six-millimeter-head metal-on-metal prostheses,” The Journal of Bone and Joint Surgery, vol. 90, pp. 142–148, 2008. View at Publisher · View at Google Scholar · View at Scopus
  12. D. J. Langton, A. P. Sprowson, T. J. Joyce et al., “Blood metal ion concentrations after hip resurfacing arthroplasty: a comparative study of articular surface replacement and Birmingham hip resurfacing arthroplasties,” Journal of Bone and Joint Surgery B, vol. 91, no. 10, pp. 1287–1295, 2009. View at Publisher · View at Google Scholar · View at Scopus
  13. W. H. Harris, “Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation,” Journal of Bone and Joint Surgery A, vol. 51, no. 4, pp. 737–755, 1969. View at Google Scholar · View at Scopus
  14. J. Dawson, R. Fitzpatrick, A. Carr, and D. Murray, “Questionnaire on the perceptions of patients about total hip replacement,” Journal of Bone and Joint Surgery B, vol. 78, no. 2, pp. 185–190, 1996. View at Google Scholar · View at Scopus
  15. J. Dawson, R. Fitzpatrick, D. Murray, and A. Carr, “Comparison of measures to assess outcomes in total hip replacement surgery,” Quality and Safety in Health Care, vol. 5, no. 2, pp. 81–88, 1996. View at Google Scholar · View at Scopus
  16. G. M. Davies, D. J. Watson, and N. Bellamy, “Comparison of the responsiveness and relative effect size of the Western Ontario and McMaster Universities Osteoarthritis Index and the short-form medical outcomes study survey in a randomized, clinical trial of osteoarthritis patients,” Arthritis Care and Research, vol. 12, no. 3, pp. 172–179, 1999. View at Google Scholar · View at Scopus
  17. J. E. Ware Jr., M. Kosinski, B. Gandek et al., “The factor structure of the SF-36 Health Survey in 10 countries: results from the IQOLA Project,” Journal of Clinical Epidemiology, vol. 51, no. 11, pp. 1159–1165, 1998. View at Publisher · View at Google Scholar · View at Scopus
  18. C. J. Kershaw, R. M. Atkins, C. A. F. Dodd, and C. J. K. Bulstrode, “Revision total hip arthroplasty for aseptic failure: a review of 276 cases,” Journal of Bone and Joint Surgery B, vol. 73, no. 4, pp. 564–568, 1991. View at Google Scholar · View at Scopus
  19. A. Malviya, J. Ramaskandhan, J. P. Holland, and E. A. Lingard, “Metal-on-metal total hip arthroplasty,” Journal of Bone and Joint Surgery A, vol. 92, no. 7, pp. 1675–1683, 2010. View at Publisher · View at Google Scholar · View at Scopus
  20. H. Pandit, S. Glyn-Jones, P. McLardy-Smith et al., “Pseudotumours associated with metal-on-metal hip resurfacings,” Journal of Bone and Joint Surgery B, vol. 90, no. 7, pp. 847–851, 2008. View at Publisher · View at Google Scholar · View at Scopus
  21. Y. S. Park, Y. W. Moon, S. J. Lim, J. M. Yang, G. Ahn, and Y. L. Choi, “Early osteolysis following second-generation metal-on-metal hip replacement,” Journal of Bone and Joint Surgery A, vol. 87, no. 7, pp. 1515–1521, 2005. View at Publisher · View at Google Scholar · View at Scopus
  22. J. J. Jacobs and N. J. Hallab, “Loosening and osteolysis associated with metal-on-metal bearings: a local effect of metal hypersensitivity?” Journal of Bone and Joint Surgery A, vol. 88, no. 6, pp. 1171–1172, 2006. View at Publisher · View at Google Scholar · View at Scopus
  23. D. R. Boardman, F. R. Middleton, and T. G. Kavanagh, “A benign psoas mass following metal-on-metal resurfacing of the hip,” Journal of Bone and Joint Surgery B, vol. 88, no. 3, pp. 402–404, 2006. View at Publisher · View at Google Scholar · View at Scopus
  24. G. Mahendra, H. Pandit, K. Kliskey, D. Murray, H. S. Gill, and N. Athanasou, “Necrotic and inflammatory changes in metal-on-metal resurfacing hip arthroplasties: relation to implant failure and pseudotumor formation,” Acta Orthopaedica, vol. 80, no. 6, pp. 653–659, 2009. View at Publisher · View at Google Scholar · View at Scopus
  25. “National Joint Registry for England and Wales,” 5th Annual Report 78, February 2012, http://www.njrcentre.org.uk/.
  26. “Withdrawal of DePuy ASR Resurfacing and XL metal on metal bearings—information for and advice to surgeons from the British Hip Society and the British Orthopaedic Association,” February 2012, http://www.britishhipsociety.com/pdfs/Withdrawal%20of%20DePuy%20ASR.pdf.
  27. D. H. Williams, N. V. Greidanus, B. A. Masri, C. P. Duncan, and D. S. Garbuz, “Prevalence of pseudotumor in asymptomatic patients after metal-on-metal hip arthroplasty,” The Journal of Bone & Joint Surgery, vol. 93, no. 23, pp. 2164–2171, 2011. View at Google Scholar
  28. D. J. Langton, S. S. Jameson, T. J. Joyce, and A. V. Nargol, “Asymptomatic patients with increased blood metal ion levels following metal on metal hip resurfacing arthroplasty: is failure imminent,” The Journal of Bone & Joint Surgery, vol. 93, supplement 4, pp. 549–550, 2011. View at Google Scholar
  29. S. S. Jameson, D. J. Langton, and A. V. F. Nargol, “Articular surface replacement of the hip: a prospective single-surgeon series,” Journal of Bone and Joint Surgery B, vol. 92, no. 1, pp. 28–37, 2010. View at Publisher · View at Google Scholar · View at Scopus
  30. D. J. Langton, T. J. Joyce, S. S. Jameson et al., “Adverse reaction to metal debris following hip resurfacing: the influence of component type, orientation and volumetric wear,” Journal of Bone and Joint Surgery B, vol. 93, no. 2, pp. 164–171, 2011. View at Publisher · View at Google Scholar · View at Scopus
  31. G. Grammatopoulos, H. Pandit, Y. M. Kwon et al., “Hip resurfacings revised for inflammatory pseudotumour have a poor outcome,” Journal of Bone and Joint Surgery B, vol. 91, no. 8, pp. 1019–1024, 2009. View at Publisher · View at Google Scholar · View at Scopus