Research Article

A New 7-Level Symmetric Multilevel Inverter with Minimum Number of Switches

Table 5

THD content.

PWM techniqueSymmetric conventional cascaded
7-level mli (%)
Asymmetric conventional cascaded
7-level mli (%)
7-level,
9 switches (%)
7-level,
7 switches (%)
7-level,
6 switches (%)
Proposed 5-switch
7-level mli (%)

PD24.2621.8418.0818.07
POD23.1320.2228.31416.1516.12
APOD22.4619.4218.5218.40