Research Article

Modeling Solar Energy Transfer through Roof Material in Africa Sub-Saharan Regions

Table 2

Ambient temperature ( ), solar irradiance (SR), wind speed (V) and the galvanized ion sheet roof room temperature ( ), the roof inner wall temperature measured ( ), and simulated ( ) and energy flux entering the room were reported.

Time (H) (°C)SR
(W/m2)
V  
(m/s)
Al-Fe
Flux

8:3033.0426.02.037.452.249.863.1
9:3033.9598.01.641.359.960.096.1
11:0035.5840.02.046.164.065.4101.6
12:0036.8853.82.050.369.271.7115.3
13:0038.0843.02.051.673.072.7115.3
14:0038.4715.42.551.265.465.876.9
15:0040.1563.02.550.161.261.660.0
16:0039.6130.00.544.747.347.513.0
17:0038.5114.02.041.642.742.98.2
18:0038.030.02.538.637.538.50.0