Research Article

Numerical Investigation of a First Stage of a Multistage Centrifugal Pump: Impeller, Diffuser with Return Vanes, and Casing

Table 2

Distribution of the pressure difference.

Blade or vane heightPressure difference p Pa
ImpellerDiffuserDiffuser return vane passages

16 mm42490874626 407792
23 mm48546892713 479427
29 mm512751108942 519683