Research Article

The Development of a Mathematical Model for the Prediction of Corrosion Rate Behaviour for Mild Steel in 0.5 M Sulphuric Acid

Table 3

Result of apparent activation energy for the absence and presence of inhibitor at different exposure time.

Inhibitor concentration
(% v/v)
Mild steel (apparent activation energy, KJ/mol)
Time (mins)

02.55 135
24.77
45.73
610.19
810.21
1010.95

02.45180
24.62
45.65
610.02
810.15
1010.75

02.35270
24.45
45.55
69.96
810.02
1010.44