Table of Contents
ISRN Transplantation
Volume 2013 (2013), Article ID 713153, 5 pages
http://dx.doi.org/10.5402/2013/713153
Clinical Study

Double-Glide Method Using Cathereep Protective Sheet As a Substitute in Descemet's Stripping Automated Endothelial Keratoplasty

1Department of Ophthalmology, Juntendo University Shizuoka Hospital, 1129, Nagaoka, Izunokuni, Shizuoka 410-2295, Japan
2Department of Ophthalmology, Juntendo University School of Medicine, 2-1-1, Hongo, Bunkyo, Tokyo 113-8421, Japan

Received 30 May 2012; Accepted 31 July 2012

Academic Editors: H.-J. Kim and W. Lim

Copyright © 2013 Hiroshi Toshida et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Linked References

  1. G. R. J. Melles, F. A. G. J. Eggink, F. Lander et al., “A surgical technique for posterior lameliar keratoplasty,” Cornea, vol. 17, no. 6, pp. 618–626, 1998. View at Publisher · View at Google Scholar · View at Scopus
  2. F. W. Price Jr. and M. O. Price, “Descemet's stripping with endothelial keratoplasty in 50 eyes: a refractive neutral corneal transplant,” Journal of Refractive Surgery, vol. 21, no. 4, pp. 339–345, 2005. View at Google Scholar · View at Scopus
  3. M. S. Gorovoy, “Descemet-stripping automated endothelial keratoplasty,” Cornea, vol. 25, no. 8, pp. 886–889, 2006. View at Publisher · View at Google Scholar · View at Scopus
  4. M. A. Terry, N. Shamie, E. S. Chen, P. M. Phillips, K. L. Hoar, and D. J. Friend, “Precut tissue for descemet's stripping automated endothelial keratoplasty. Vision, astigmatism, and endothelial survival,” Ophthalmology, vol. 116, no. 2, pp. 248–256, 2009. View at Publisher · View at Google Scholar · View at Scopus
  5. M. Busin, P. R. Bhatt, and V. Scorcia, “A modified technique for descemet membrane stripping automated endothelial keratoplasty to minimize endothelial cell loss,” Archives of Ophthalmology, vol. 126, no. 8, pp. 1133–1137, 2008. View at Publisher · View at Google Scholar · View at Scopus
  6. A. Kobayashi, H. Yokogawa, and K. Sugiyama, “Descemet stripping with automated endothelial keratoplasty for bullous keratopathies secondary to argon laser iridotomy—preliminary results and usefulness of double-glide donor insertion technique,” Cornea, vol. 27, no. 1, pp. S62–S69, 2008. View at Publisher · View at Google Scholar · View at Scopus
  7. H. Toshida, T. Ohta, MurakamiA, A. Kobayashi, and Y. Sugiyama, “Descemet stripping automated endothelial keratoplasty for microcornea,” apanese Journal of Ophthalmology, vol. 56, no. 5, pp. 436–440, 2012. View at Google Scholar
  8. J. T. Holladay and T. C. Prager, “Mean visual acuity,” American Journal of Ophthalmology, vol. 111, no. 3, pp. 372–374, 1991. View at Google Scholar · View at Scopus
  9. F. L. Ferris III, A. Kassoff, G. H. Bresnick, and L. Bailey, “New visual acuity charts for clinical research,” American Journal of Ophthalmology, vol. 94, no. 1, pp. 91–96, 1982. View at Google Scholar · View at Scopus
  10. W. B. Khor, J. S. Mehta, and D. T. H. Tan, “Descemet stripping automated endothelial keratoplasty with a graft insertion device: surgical technique and early clinical results,” American Journal of Ophthalmology, vol. 151, no. 2, pp. 223.e2–232.e2, 2011. View at Publisher · View at Google Scholar · View at Scopus
  11. C. Macaluso, “Closed-chamber pulling-injection system for donor graft insertion in endothelial keratoplasty,” Journal of Cataract and Refractive Surgery, vol. 34, no. 3, pp. 353–356, 2008. View at Publisher · View at Google Scholar · View at Scopus
  12. J. S. Mehta, Y. M. Por, R. W. Beuerman, and D. T. Tan, “Glide insertion technique for donor cornea lenticule during Descemet's stripping automated endothelial keratoplasty,” Journal of Cataract and Refractive Surgery, vol. 33, no. 11, pp. 1846–1850, 2007. View at Publisher · View at Google Scholar · View at Scopus