Review Article
Alternate Strategies for Conversion of Waste Plastic to Fuels
Table 4
Main operating parameters for pyrolysis process [
7].
| Parameters | Conventional | Fast | Flash |
| Pyrolysis temprature (K) | 550–900 | 850–1250 | 1050–1300 | Heating rate (K/s) | 0.1–1 | 10–200 | >1000 | Particle size (mm) | 5–50 | <1 | <0.2 | Solid residence (s) | 300–3600 | 0.5–10 | <0.5 |
|
|