Table of Contents
ISRN Ophthalmology
Volume 2013, Article ID 956504, 5 pages
http://dx.doi.org/10.1155/2013/956504
Clinical Study

Short-Term Effect of Standard Automated Perimetry Testing on Intraocular Pressure in Patients with Open-Angle Glaucoma

Department of Ophthalmology, Kangdong Sacred Heart Hospital, Hallym University College of Medicine, 150 Seongnae-gil, Gangdong-gu, Seoul 134-701, Republic of Korea

Received 19 December 2012; Accepted 6 January 2013

Academic Editors: H. Ahmadieh and U. U. Inan

Copyright © 2013 Chang Mok Lee and Young Cheol Yoo. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Linked References

  1. T. Schmidt, “The use of the Goldmann applanation tonometer,” Transactions of the Ophthalmological Societies of the United Kingdom, vol. 79, pp. 637–650, 1959. View at Google Scholar · View at Scopus
  2. H. C. Agarwal, V. Gulati, and R. Sihota, “Visual field assessment in glaucoma: comparative evaluation of manual kinetic Goldmann perimetry and automated static perimetry,” Indian Journal of Ophthalmology, vol. 48, no. 4, pp. 301–306, 2000. View at Google Scholar · View at Scopus
  3. S. M. Recupero, M. T. Contestabile, L. Taverniti, G. M. Villani, and V. Recupero, “Open-angle glaucoma: variations in the intraocular pressure after visual field examination,” Journal of Glaucoma, vol. 12, no. 2, pp. 114–118, 2003. View at Publisher · View at Google Scholar · View at Scopus
  4. G. Rebolleda, C. Rodríguez-Villace, M. V. Anton et al., “Variations in intraocular pressure after visual field examination,” Journal of Glaucoma, vol. 13, no. 2, pp. 178–179, 2004. View at Publisher · View at Google Scholar · View at Scopus
  5. L. Martin, “Intraocular pressure before and after visual field examination,” Eye, vol. 21, no. 12, pp. 1479–1481, 2007. View at Publisher · View at Google Scholar · View at Scopus
  6. A. H. Neufeld, S. P. Bartels, and J. H. K. Liu, “Laboratory and clinical studies on the mechanism of action of timolol,” Survey of Ophthalmology, vol. 28, pp. 286–292, 1983. View at Google Scholar · View at Scopus
  7. T. R. Walters, “Development and use of brimonidine in treating acute and chronic elevations of intraocular pressure: a review of safety, efficacy, dose response, and dosing studies,” Survey of Ophthalmology, vol. 41, no. 1, pp. S19–S26, 1996. View at Google Scholar · View at Scopus
  8. R. N. Weinreb, C. B. Toris, B. A. T. Gabelt, J. D. Lindsey, and P. L. Kaufman, “Effects of prostaglandins on the aqueous humor outflow pathways,” Survey of Ophthalmology, vol. 47, no. 4, pp. S53–S64, 2002. View at Publisher · View at Google Scholar · View at Scopus
  9. T. H. Maren, “The development of topical carbonic anhydrase inhibitors,” Journal of Glaucoma, vol. 4, no. 1, pp. 49–62, 1995. View at Google Scholar · View at Scopus
  10. C. M. Lee and Y. C. Yu, “Intraocular pressure measurement with the noncontact tonometer and rebound tonometer through plano soft contact lenses,” Journal of Korean Ophthalmological Society, vol. 53, pp. 662–667, 2012. View at Google Scholar
  11. M. A. Kass, D. K. Heuer, E. J. Higginbotham et al., “The Ocular Hypertension Treatment Study: a randomized trial determines that topical ocular hypotensive medication delays or prevents the onset of primary open-angle glaucoma,” Archives of Ophthalmology, vol. 120, no. 6, pp. 701–713, 2002. View at Google Scholar · View at Scopus
  12. A. Heijl, M. C. Leske, B. Bengtsson, L. Hyman, B. Bengtsson, and M. Hussein, “Reduction of intraocular pressure and glaucoma progression: results from the Early Manifest Glaucoma Trial,” Archives of Ophthalmology, vol. 120, no. 10, pp. 1268–1279, 2002. View at Google Scholar · View at Scopus
  13. N. Ni, J. C. Tsai, M. B. Shields, and N. A. Loewen, “Elevation of intraocular pressure in glaucoma patients after automated visual field testing,” Journal of Glaucoma, vol. 21, no. 9, pp. 590–595, 2012. View at Publisher · View at Google Scholar · View at Scopus
  14. P. R. Lichter and T. J. Bergstrom, “Premature ventricular systole detection by applanation tonometry,” American Journal of Ophthalmology, vol. 81, no. 6, pp. 797–803, 1976. View at Google Scholar · View at Scopus
  15. J. T. Holladay, M. E. Allison, and T. C. Prager, “Goldmann applanation tonometry in patients with regular corneal astigmatism,” American Journal of Ophthalmology, vol. 96, no. 1, pp. 90–93, 1983. View at Google Scholar · View at Scopus
  16. R. A. Moses and R. J. Arnzen, “Instantaneous tonometry,” Archives of Ophthalmology, vol. 101, no. 2, pp. 249–252, 1983. View at Google Scholar · View at Scopus
  17. S. Asrani, A. Chatterjee, D. K. Wallace, C. Santiago-Turla, and S. Stinnett, “Evaluation of the ICare rebound tonometer as a home intraocular pressure monitoring device,” Journal of Glaucoma, vol. 20, no. 2, pp. 74–79, 2011. View at Publisher · View at Google Scholar · View at Scopus
  18. J. M. Martinez-de-la-Casa, J. Garcia-Feijoo, A. Castillo, and J. Garcia-Sanchez, “Reproducibility and clinical evaluation of rebound tonometry,” Investigative Ophthalmology and Visual Science, vol. 46, no. 12, pp. 4578–4580, 2005. View at Publisher · View at Google Scholar · View at Scopus
  19. J. D. Brandt, “The myth of clinical precision,” Ophthalmology, vol. 116, no. 1, pp. 1.e1–2.e1, 2009. View at Publisher · View at Google Scholar · View at Scopus
  20. M. M. Whitacre and R. Stein, “Sources of error with use of Goldmann-type tonometers,” Survey of Ophthalmology, vol. 38, no. 1, pp. 1–30, 1993. View at Publisher · View at Google Scholar · View at Scopus
  21. F. M. C. Grignolo Bongioanni and B. Boles Carenini, “Variations of intraocular pressure induced by psychological stress,” Klinische Monatsblatter fur Augenheilkunde, vol. 170, no. 4, pp. 562–569, 1977. View at Google Scholar · View at Scopus
  22. C. Erb, S. Brody, and H. Rau, “Influence of mental and physical stress on intraocular pressure—a pilot study,” Klinische Monatsblatter fur Augenheilkunde, vol. 212, no. 5, pp. 270–274, 1998. View at Google Scholar · View at Scopus
  23. H. S. Ripley and H. G. Wolff, “Life situations, emotions, and glaucoma,” Psychosomatic Medicine, vol. 12, no. 4, pp. 215–224, 1950. View at Google Scholar · View at Scopus
  24. M. A. Kass, “Standardizing the measurement of intraocular pressure for clinical research: guidelines from the Eye Care Technology Forum,” Ophthalmology, vol. 103, no. 1, pp. 183–185, 1996. View at Google Scholar · View at Scopus
  25. A. Hager and W. Wiegand, “Methods of measuring intraocular pressure independently of central corneal thickness,” Ophthalmologe, vol. 105, no. 9, pp. 840–844, 2008. View at Publisher · View at Google Scholar · View at Scopus
  26. P. Brusini, M. L. Salvetat, M. Zeppieri, C. Tosoni, and L. Parisi, “Comparison of ICare tonometer with Goldmann applanation tonometer in glaucoma patients,” Journal of Glaucoma, vol. 15, no. 3, pp. 213–217, 2006. View at Publisher · View at Google Scholar · View at Scopus
  27. L. H. van der Jagt and N. M. Jansonius, “Three portable tonometers, the TGDc-01, the ICARE and the Tonopen XL, compared with each other and with Goldmann applanation tonometry,” Ophthalmic and Physiological Optics, vol. 25, no. 5, pp. 429–435, 2005. View at Publisher · View at Google Scholar · View at Scopus
  28. J. M. Martinez-de-la-Casa, J. Garcia-Feijoo, E. Vico et al., “Effect of corneal thickness on dynamic contour, rebound, and goldmann tonometry,” Ophthalmology, vol. 113, no. 12, pp. 2156–2162, 2006. View at Publisher · View at Google Scholar · View at Scopus
  29. A. Sahin, H. Basmak, L. Niyaz, and N. Yildirim, “Reproducibility and tolerability of the ICare rebound tonometer in school children,” Journal of Glaucoma, vol. 16, no. 2, pp. 185–188, 2007. View at Publisher · View at Google Scholar · View at Scopus
  30. W. S. Chui, A. Lam, D. Chen, and R. Chiu, “The influence of corneal properties on rebound tonometry,” Ophthalmology, vol. 115, no. 1, pp. 80–84, 2008. View at Publisher · View at Google Scholar · View at Scopus
  31. S. Munkwitz, A. Elkarmouty, E. M. Hoffmann, N. Pfeiffer, and H. Thieme, “Comparison of the iCare rebound tonometer and the Goldmann applanation tonometer over a wide IOP range,” Graefe's Archive for Clinical and Experimental Ophthalmology, vol. 246, no. 6, pp. 875–879, 2008. View at Publisher · View at Google Scholar · View at Scopus
  32. Y. C. Yu, S. H. Kim, Y. J. Kim, and K. H. Park, “Comparison of the intraocular pressure measurement between rebound tonometer and tonopen in rats,” Journal of Korean Ophthalmological Society, vol. 48, pp. 135–141, 2007. View at Google Scholar