Research Article

Effect of Fracture Aperture on P-Wave Attenuation: A Seismic Physical Modelling Study

Table 2

Summary of data acquisition geometry—all the acquisition parameters given are not converted to actual scales. The model dimensions and acquisition parameters are scaled up by 1 : 10000 while the frequency is scaled down by 10000 : 1.

Water depth to base model (mm)100
Number of shots220
Shot interval (mm)2
Receiver interval (mm)2
Number of receivers120
Minimum offset (mm)16
Maximum offset (mm)254
Fold of cover60
Number of samples4096
Sample rate (μs)0.1