Research Article

Damping Evaluation of Linseed Oil-Based Engineering Elastomers by Vibration Response Method

Table 2

Tensile test results of elastomers.

SETSample IDCrosslinking density × 102
(mol/m3) [21]
Ultimate tensile strength ( ) (MPa)Elongation at break ( ) (%)Young’s modulus ( ) (MPa)Toughness (MPa)

IS1Lin454.343.7111710.272.88
S2Lin503.502.661447.232.16
S3Lin552.531.931545.541.78
S4Lin601.151.05981.100.51

IIS5Lin504.303.6919.801.95
S6Lin552.812.21155.461.44
S7Lin602.010.78831.320.34
S8Lin651.040.371440.270.31