Research Article

Development and Performance Evaluation of Corrosion Resistance Self-Healing Coating

Figure 6

(a) Initial EIS result of self-healing coated sample. (b) EIS result after 48 h of exposure of self-healing coated sample in 3.5% NaCl solution. (c) EIS result after 96 h of exposure of self-healing coated sample in 3.5% NaCl solution. (d) Initial EIS result of sol-gel coated sample (without any capsule). (e) EIS result after 96 h of exposure of sol-gel coated sample (without any capsule) in 3.5% NaCl solution.
979323.fig.006a
(a)
979323.fig.006b
(b)
979323.fig.006c
(c)
979323.fig.006d
(d)
979323.fig.006e
(e)