Research Article
Resiliency-Driven Approach of DC Microgrid Voltage Regulation Based on Droop Index Control for High Step-Up DC-DC Converter
Table 1
DC shunt motor specifications [
34,
35].
| Symbols | Parameters | Values | On 400 V bus side converter | On 200 V bus side converter |
| Ra | DC shunt motor armature resistance | 2.5 Ohms | 1.8 Ohms | Rf | DC shunt motor field resistance | 250 Ohms | 225 Ohms | La | DC shunt motor armature inductance | 0.01 mH | 0.016 mH | | Back electromotive force constant | 1.28 V/rad/s | 1.23 V/rad/s | J | Mass moment of inertia | 0.0465 Kg m2 | 0.0543 Kg m2 | Bm | Viscous friction coefficient | 0.0687 N-m/rad/s | 0.0492 N-m/rad/s | Va | DC shunt motor armature voltage | 400 V | 200 V | Ia | Armature current of DC shunt motor | 2.4 A | 1.5 A | If | Field current DC shunt motor | 1.6 A | 0.9 A |
|
|